Hikvision 8-Zone Conventional Fire Alarm Control Panel – HF-C108

Hikvision HF-C108 8-Zone Fire Alarm Control Panel is a conventional fire alarm panel supporting up to 32 compatible conventional devices per zone, with 256-device total capacity.
In Stock
Shop With Confidence

Product Description:
Hikvision HF-C108 8-Zone Fire Alarm Control Panel is a conventional fire alarm control panel designed to monitor and manage compatible fire detection and alarm devices across eight independent zones. With support for up to 32 conventional devices in each zone, the HF-C108 provides a total rated capacity of up to 256 conventional devices for suitable fire detection installations.
The Hikvision 8-Zone Fire Alarm Control Panel can be used as the central control unit of a conventional fire alarm system, connecting compatible smoke detectors, heat detectors, manual call points and alarm notification devices. Its zone-based architecture allows different areas of a building to be monitored through one central panel.
Key Features
- 8 conventional fire alarm zones
- Up to 32 conventional devices per zone
- Up to 256 conventional devices in total
- Compatible with conventional smoke detectors
- Supports heat detectors and manual call points
- Fire bell outputs
- Fire alarm relay output
- Fault relay output
- Ethernet interface
- RS-485 interface
- USB interface
- 4 auxiliary power interfaces
- 24V auxiliary output
- Local silence function
- Reset function
- Self-test function
- Ultra-slim metal cabinet
- Wall mounting and built-in installation support
- 110V–240V AC main power supply
- Two 12V, 2200mAh backup batteries
8-Zone Conventional Fire Alarm Control
The HF-C108 Conventional Fire Alarm Panel provides eight separate detection zones for monitoring different areas within a protected building. Each zone can support up to 32 conventional devices, giving the system a rated capacity of up to 256 devices across all eight zones.
Zone-based monitoring provides a structured way to organize detectors and manual call points throughout a building. When an alarm or fault condition occurs, the control panel provides status information to help responsible personnel identify the relevant zone and respond appropriately.
Support for Conventional Fire Detection Devices
The Hikvision HF-C108 Fire Alarm Control Panel is designed to work with compatible conventional fire detection equipment. Depending on the system design, connected devices can include smoke detectors, heat detectors and manual call points, together with suitable sounders, strobes or fire bells.
This allows the panel to serve as the central point for a conventional fire alarm installation. Device compatibility, detector quantities and system configuration should always be confirmed against the manufacturer’s specifications and the requirements of the individual project.
Up to 256 Conventional Devices
One of the key features of the Hikvision 8-Zone Fire Alarm Control Panel is its device capacity. The HF-C108 supports up to 32 conventional devices per zone, resulting in a rated capacity of up to 256 conventional devices across eight zones.
This makes the panel suitable for installations requiring more detection zones than smaller conventional control panels. Dividing the building into eight zones can also help organize detection coverage according to different rooms, floors, sections or risk areas.
Alarm and Fault Monitoring
The HF-C108 Fire Alarm Control Panel provides monitoring functions for both fire alarm and fault conditions. Dedicated indicators help communicate the current status of the system, while the panel’s audible buzzer provides a local warning when an alarm condition occurs.
The system also provides dedicated fire alarm and fault relay outputs for integration with compatible external equipment. These interfaces can be used as part of an appropriately designed fire alarm and monitoring installation.
Audible and Visual Alarm Indication
The Hikvision HF-C108 incorporates an alarm indicator and high-tone buzzer to provide local audio-visual notification. Hikvision documentation specifies an internal high-tone buzzer and an alarm sound pressure specification of 75dB at 1 metre for the control panel.
The panel also provides two fire bell outputs for compatible external notification devices. These outputs allow the conventional fire alarm system to provide audible notification in the protected areas according to the installation design.
Ethernet, RS-485 and USB Interfaces
The Hikvision HF-C108 Conventional Fire Alarm Panel includes multiple communication and connection interfaces. The specified interfaces include Ethernet, RS-485 and USB, along with auxiliary power connections and dedicated alarm and fault outputs.
These connection options provide flexibility when the control panel needs to be integrated with compatible equipment or configured as part of a broader fire protection system.
Backup Battery Power
The HF-C108 8-Zone Fire Alarm Control Panel supports backup power through two 12V, 2200mAh sealed lead-acid batteries. The main power supply is specified as 110V to 240V AC with a frequency range of 50Hz to 60Hz.
The backup battery system is designed to provide standby power when the primary mains supply is unavailable. Batteries should be installed, tested and maintained according to the manufacturer’s instructions and applicable fire safety requirements.
Local Silence, Reset and Self-Test
The Hikvision HF-C108 includes local silence, reset and self-test functions. These controls support routine operation, testing and maintenance of the fire alarm control panel.
The self-test function can be used by authorized personnel to check system operation, while the silence and reset controls provide local management during appropriate alarm, testing and maintenance procedures.
Ultra-Slim Metal Cabinet
The Hikvision 8-Zone Fire Alarm Control Panel features an ultra-slim metal cabinet with hidden hinges. The design supports both wall mounting and built-in installation, providing flexibility for different installation environments.
The specified dimensions are approximately 300mm wide, 220mm high and 80mm deep. The metal enclosure provides a practical housing for the control electronics, connection interfaces and backup power components.
Communication Distance
The HF-C108 Conventional Fire Alarm Panel supports a specified communication distance of up to 500 metres when using RVS 2 × 1.5mm² flame-retardant cable according to the manufacturer’s documentation.
The actual achievable distance can depend on cable selection, connected devices, installation conditions and system configuration. Fire alarm wiring should be installed and tested by appropriately qualified personnel.
Suitable Applications
The Hikvision HF-C108 Fire Alarm Control Panel is designed for suitable conventional fire detection installations requiring multiple detection zones. Potential applications include:
- Commercial buildings
- Factories and industrial facilities
- Warehouses
- Offices
- Educational buildings
- Residential and multi-unit properties
- Public buildings
- Small and medium-sized facilities
Hikvision documentation identifies applications including dormitories, nursing homes, markets, high-rise buildings, factories and other small and medium-sized environments with concentrated protection areas.
English Display and System Status
The Hikvision HF-C108 uses an English-language alarm display designed to provide clear system information. The panel also provides status indicators for conditions such as fire alarm, manual call point alarm, general fault, disabled zones, earth fault, mains supply and battery status.
Clear status information can help authorized personnel understand the condition of the fire alarm system and identify situations that require inspection or maintenance.
Professional Conventional Fire Alarm Solution
The Hikvision 8-Zone Fire Alarm Control Panel provides centralized monitoring and control for a conventional fire detection system. With eight detection zones and support for up to 32 conventional devices per zone, it can organize a substantial number of compatible detection points across different areas.
The combination of fire alarm outputs, fault monitoring, backup power, communication interfaces and local control functions makes the HF-C108 suitable for appropriately designed conventional fire alarm installations.
Technical Specifications
- Model: HF-C108
- System type: Conventional fire alarm control panel
- Number of zones: 8
- Devices per zone: Up to 32 conventional devices
- Total rated capacity: Up to 256 conventional devices
- Main power: 110V–240V AC, 50Hz–60Hz
- Backup power: 2 × 12V, 2200mAh sealed lead-acid batteries
- Communication distance: Up to 500m with specified cable
- Alarm sound pressure: 75dB @ 1m
- Ethernet interface: 1
- RS-485 interface: 1
- USB interface: 1
- Auxiliary power interfaces: 4
- 24V output: 1 way, 500mA
- Fire bell outputs: 2 ways, 27.5V/500mA total
- Fire alarm relay output: 1 way
- Fault relay output: 1 way
- Dimensions: 300 × 220 × 80mm
- Operating temperature: -10°C to +55°C
- Operating humidity: 5%–95% RH, non-condensing
- Enclosure material: Metal
- Weight: Approximately 4.9kg with batteries and packaging
Why Choose Hikvision HF-C108?
The Hikvision HF-C108 8-Zone Fire Alarm Control Panel provides eight conventional detection zones and a rated capacity of up to 256 conventional devices. Its multiple interfaces, alarm and fault outputs, battery backup, self-test function and flexible mounting design make it a practical control panel for suitable conventional fire alarm systems.
The panel should be installed, programmed, tested and maintained by appropriately qualified personnel in accordance with Hikvision’s instructions, the system design and applicable local fire safety requirements.
FAQs
What is the Hikvision HF-C108 Fire Alarm Control Panel?
The Hikvision HF-C108 is an 8-zone conventional fire alarm control panel designed to monitor and control compatible conventional fire detection and alarm devices.
How many zones does the HF-C108 have?
The HF-C108 has eight conventional fire alarm detection zones.
How many devices can the Hikvision HF-C108 support?
The panel supports up to 32 conventional devices per zone, giving it a rated total capacity of up to 256 conventional devices.
What devices can be connected to the HF-C108?
Compatible conventional devices can include smoke detectors, heat detectors and manual call points, together with suitable alarm notification devices.
Does the Hikvision HF-C108 have battery backup?
Yes. The panel uses two 12V, 2200mAh sealed lead-acid batteries for backup power.
Does the HF-C108 support Ethernet?
Yes. The HF-C108 includes one Ethernet interface, along with RS-485 and USB interfaces.
Does the HF-C108 have a self-test function?
Yes. The panel includes a self-test function as well as local silence and reset functions.
What is the communication distance of the HF-C108?
The specified maximum communication distance is up to 500 metres when using the recommended RVS 2 × 1.5mm² flame-retardant cable.
What is the power supply of the Hikvision HF-C108?
The main power supply is specified as 110V–240V AC at 50Hz–60Hz, with two 12V, 2200mAh backup batteries.
What are the dimensions of the HF-C108?
The Hikvision HF-C108 measures approximately 300mm wide × 220mm high × 80mm deep.
Can the HF-C108 be wall mounted?
Yes. The panel supports wall mounting and built-in installation according to the product documentation.
What is the operating temperature of the HF-C108?
The specified operating temperature range is -10°C to +55°C.
Is the HF-C108 suitable for industrial buildings?
Yes. Hikvision documentation identifies factories and other small and medium-sized environments among the suitable application scenarios for this conventional fire alarm control panel.
Related products
₨80,000.00
₨4,500.00
₨25,000.00
₨12,000.00

Hikvision 8-Zone Conventional Fire Alarm Control Panel – HF-C108

Hikvision HF-C108 8-Zone Fire Alarm Control Panel is a conventional fire alarm panel supporting up to 32 compatible conventional devices per zone, with 256-device total capacity.
In Stock
Shop With Confidence

Product Description:
Hikvision HF-C108 8-Zone Fire Alarm Control Panel is a conventional fire alarm control panel designed to monitor and manage compatible fire detection and alarm devices across eight independent zones. With support for up to 32 conventional devices in each zone, the HF-C108 provides a total rated capacity of up to 256 conventional devices for suitable fire detection installations.
The Hikvision 8-Zone Fire Alarm Control Panel can be used as the central control unit of a conventional fire alarm system, connecting compatible smoke detectors, heat detectors, manual call points and alarm notification devices. Its zone-based architecture allows different areas of a building to be monitored through one central panel.
Key Features
- 8 conventional fire alarm zones
- Up to 32 conventional devices per zone
- Up to 256 conventional devices in total
- Compatible with conventional smoke detectors
- Supports heat detectors and manual call points
- Fire bell outputs
- Fire alarm relay output
- Fault relay output
- Ethernet interface
- RS-485 interface
- USB interface
- 4 auxiliary power interfaces
- 24V auxiliary output
- Local silence function
- Reset function
- Self-test function
- Ultra-slim metal cabinet
- Wall mounting and built-in installation support
- 110V–240V AC main power supply
- Two 12V, 2200mAh backup batteries
8-Zone Conventional Fire Alarm Control
The HF-C108 Conventional Fire Alarm Panel provides eight separate detection zones for monitoring different areas within a protected building. Each zone can support up to 32 conventional devices, giving the system a rated capacity of up to 256 devices across all eight zones.
Zone-based monitoring provides a structured way to organize detectors and manual call points throughout a building. When an alarm or fault condition occurs, the control panel provides status information to help responsible personnel identify the relevant zone and respond appropriately.
Support for Conventional Fire Detection Devices
The Hikvision HF-C108 Fire Alarm Control Panel is designed to work with compatible conventional fire detection equipment. Depending on the system design, connected devices can include smoke detectors, heat detectors and manual call points, together with suitable sounders, strobes or fire bells.
This allows the panel to serve as the central point for a conventional fire alarm installation. Device compatibility, detector quantities and system configuration should always be confirmed against the manufacturer’s specifications and the requirements of the individual project.
Up to 256 Conventional Devices
One of the key features of the Hikvision 8-Zone Fire Alarm Control Panel is its device capacity. The HF-C108 supports up to 32 conventional devices per zone, resulting in a rated capacity of up to 256 conventional devices across eight zones.
This makes the panel suitable for installations requiring more detection zones than smaller conventional control panels. Dividing the building into eight zones can also help organize detection coverage according to different rooms, floors, sections or risk areas.
Alarm and Fault Monitoring
The HF-C108 Fire Alarm Control Panel provides monitoring functions for both fire alarm and fault conditions. Dedicated indicators help communicate the current status of the system, while the panel’s audible buzzer provides a local warning when an alarm condition occurs.
The system also provides dedicated fire alarm and fault relay outputs for integration with compatible external equipment. These interfaces can be used as part of an appropriately designed fire alarm and monitoring installation.
Audible and Visual Alarm Indication
The Hikvision HF-C108 incorporates an alarm indicator and high-tone buzzer to provide local audio-visual notification. Hikvision documentation specifies an internal high-tone buzzer and an alarm sound pressure specification of 75dB at 1 metre for the control panel.
The panel also provides two fire bell outputs for compatible external notification devices. These outputs allow the conventional fire alarm system to provide audible notification in the protected areas according to the installation design.
Ethernet, RS-485 and USB Interfaces
The Hikvision HF-C108 Conventional Fire Alarm Panel includes multiple communication and connection interfaces. The specified interfaces include Ethernet, RS-485 and USB, along with auxiliary power connections and dedicated alarm and fault outputs.
These connection options provide flexibility when the control panel needs to be integrated with compatible equipment or configured as part of a broader fire protection system.
Backup Battery Power
The HF-C108 8-Zone Fire Alarm Control Panel supports backup power through two 12V, 2200mAh sealed lead-acid batteries. The main power supply is specified as 110V to 240V AC with a frequency range of 50Hz to 60Hz.
The backup battery system is designed to provide standby power when the primary mains supply is unavailable. Batteries should be installed, tested and maintained according to the manufacturer’s instructions and applicable fire safety requirements.
Local Silence, Reset and Self-Test
The Hikvision HF-C108 includes local silence, reset and self-test functions. These controls support routine operation, testing and maintenance of the fire alarm control panel.
The self-test function can be used by authorized personnel to check system operation, while the silence and reset controls provide local management during appropriate alarm, testing and maintenance procedures.
Ultra-Slim Metal Cabinet
The Hikvision 8-Zone Fire Alarm Control Panel features an ultra-slim metal cabinet with hidden hinges. The design supports both wall mounting and built-in installation, providing flexibility for different installation environments.
The specified dimensions are approximately 300mm wide, 220mm high and 80mm deep. The metal enclosure provides a practical housing for the control electronics, connection interfaces and backup power components.
Communication Distance
The HF-C108 Conventional Fire Alarm Panel supports a specified communication distance of up to 500 metres when using RVS 2 × 1.5mm² flame-retardant cable according to the manufacturer’s documentation.
The actual achievable distance can depend on cable selection, connected devices, installation conditions and system configuration. Fire alarm wiring should be installed and tested by appropriately qualified personnel.
Suitable Applications
The Hikvision HF-C108 Fire Alarm Control Panel is designed for suitable conventional fire detection installations requiring multiple detection zones. Potential applications include:
- Commercial buildings
- Factories and industrial facilities
- Warehouses
- Offices
- Educational buildings
- Residential and multi-unit properties
- Public buildings
- Small and medium-sized facilities
Hikvision documentation identifies applications including dormitories, nursing homes, markets, high-rise buildings, factories and other small and medium-sized environments with concentrated protection areas.
English Display and System Status
The Hikvision HF-C108 uses an English-language alarm display designed to provide clear system information. The panel also provides status indicators for conditions such as fire alarm, manual call point alarm, general fault, disabled zones, earth fault, mains supply and battery status.
Clear status information can help authorized personnel understand the condition of the fire alarm system and identify situations that require inspection or maintenance.
Professional Conventional Fire Alarm Solution
The Hikvision 8-Zone Fire Alarm Control Panel provides centralized monitoring and control for a conventional fire detection system. With eight detection zones and support for up to 32 conventional devices per zone, it can organize a substantial number of compatible detection points across different areas.
The combination of fire alarm outputs, fault monitoring, backup power, communication interfaces and local control functions makes the HF-C108 suitable for appropriately designed conventional fire alarm installations.
Technical Specifications
- Model: HF-C108
- System type: Conventional fire alarm control panel
- Number of zones: 8
- Devices per zone: Up to 32 conventional devices
- Total rated capacity: Up to 256 conventional devices
- Main power: 110V–240V AC, 50Hz–60Hz
- Backup power: 2 × 12V, 2200mAh sealed lead-acid batteries
- Communication distance: Up to 500m with specified cable
- Alarm sound pressure: 75dB @ 1m
- Ethernet interface: 1
- RS-485 interface: 1
- USB interface: 1
- Auxiliary power interfaces: 4
- 24V output: 1 way, 500mA
- Fire bell outputs: 2 ways, 27.5V/500mA total
- Fire alarm relay output: 1 way
- Fault relay output: 1 way
- Dimensions: 300 × 220 × 80mm
- Operating temperature: -10°C to +55°C
- Operating humidity: 5%–95% RH, non-condensing
- Enclosure material: Metal
- Weight: Approximately 4.9kg with batteries and packaging
Why Choose Hikvision HF-C108?
The Hikvision HF-C108 8-Zone Fire Alarm Control Panel provides eight conventional detection zones and a rated capacity of up to 256 conventional devices. Its multiple interfaces, alarm and fault outputs, battery backup, self-test function and flexible mounting design make it a practical control panel for suitable conventional fire alarm systems.
The panel should be installed, programmed, tested and maintained by appropriately qualified personnel in accordance with Hikvision’s instructions, the system design and applicable local fire safety requirements.
FAQs
What is the Hikvision HF-C108 Fire Alarm Control Panel?
The Hikvision HF-C108 is an 8-zone conventional fire alarm control panel designed to monitor and control compatible conventional fire detection and alarm devices.
How many zones does the HF-C108 have?
The HF-C108 has eight conventional fire alarm detection zones.
How many devices can the Hikvision HF-C108 support?
The panel supports up to 32 conventional devices per zone, giving it a rated total capacity of up to 256 conventional devices.
What devices can be connected to the HF-C108?
Compatible conventional devices can include smoke detectors, heat detectors and manual call points, together with suitable alarm notification devices.
Does the Hikvision HF-C108 have battery backup?
Yes. The panel uses two 12V, 2200mAh sealed lead-acid batteries for backup power.
Does the HF-C108 support Ethernet?
Yes. The HF-C108 includes one Ethernet interface, along with RS-485 and USB interfaces.
Does the HF-C108 have a self-test function?
Yes. The panel includes a self-test function as well as local silence and reset functions.
What is the communication distance of the HF-C108?
The specified maximum communication distance is up to 500 metres when using the recommended RVS 2 × 1.5mm² flame-retardant cable.
What is the power supply of the Hikvision HF-C108?
The main power supply is specified as 110V–240V AC at 50Hz–60Hz, with two 12V, 2200mAh backup batteries.
What are the dimensions of the HF-C108?
The Hikvision HF-C108 measures approximately 300mm wide × 220mm high × 80mm deep.
Can the HF-C108 be wall mounted?
Yes. The panel supports wall mounting and built-in installation according to the product documentation.
What is the operating temperature of the HF-C108?
The specified operating temperature range is -10°C to +55°C.
Is the HF-C108 suitable for industrial buildings?
Yes. Hikvision documentation identifies factories and other small and medium-sized environments among the suitable application scenarios for this conventional fire alarm control panel.