Hikvision HF-C104 Fire Alarm Control Panel is a 4-zone conventional fire alarm control panel designed to manage and monitor conventional fire detection devices across multiple protected areas. The HF-C104 supports up to 32 conventional devices per zone, providing a total capacity of up to 128 devices for suitable fire alarm installations.
The Hikvision 4-Zone Fire Alarm Control Panel can work with compatible conventional smoke detectors, heat detectors, manual call points and notification devices to create a complete fire detection and alarm system. Its combination of zone monitoring, alarm outputs, fault monitoring and multiple communication interfaces makes it suitable for a range of commercial and industrial installations.
Key Features
- 4 conventional fire alarm zones
- Up to 32 conventional devices per zone
- Up to 128 conventional devices in total
- Supports smoke detectors, heat detectors and manual call points
- Fire bell outputs
- Fire alarm relay output
- Fault relay output
- Ethernet interface
- RS-485 interface
- USB interface
- 4 auxiliary power interfaces
- 24V auxiliary output
- Local silence function
- Reset function
- Self-test function
- Metal cabinet construction
- 110V–240V AC main power supply
- Two 12V, 2200mAh backup batteries
4-Zone Conventional Fire Alarm Panel
The HF-C104 Conventional Fire Alarm Panel provides four independent detection zones for organizing and monitoring different areas of a building. Each zone can support up to 32 compatible conventional devices, giving the panel a maximum rated capacity of 128 conventional devices.
Zone-based monitoring makes it easier for users to identify the affected area when a fire alarm or fault condition occurs. The system can monitor connected devices and wiring conditions, helping provide clear information about the status of the fire detection installation.
Wide Device Compatibility
The Hikvision HF-C104 Fire Alarm Control Panel is designed to work with compatible conventional fire detection and alarm devices. These can include smoke detectors, heat detectors, manual call points, sounders, bells and other compatible notification equipment.
This allows installers to configure an appropriate conventional fire alarm system according to the requirements of the protected building. Device selection and system configuration should always be based on the specific fire risks, building layout and applicable fire safety requirements.
Up to 128 Conventional Devices
The Hikvision 4-Zone Fire Alarm Control Panel supports up to 32 conventional devices on each zone. With four zones available, the HF-C104 provides a rated capacity of up to 128 conventional devices.
This capacity makes the panel suitable for small and medium-sized fire protection installations where multiple areas need to be monitored from a central control point.
Fire Alarm and Fault Monitoring
The HF-C104 Conventional Fire Alarm Panel provides dedicated indicators and monitoring functions for fire alarm and fault conditions. The panel can identify alarm conditions and provide corresponding visual and audible indications.
The system also includes fire alarm and fault relay outputs, allowing compatible external equipment or monitoring systems to receive the relevant status signals. Correct installation and configuration should be performed by qualified personnel.
Integrated Audible Alarm
The Hikvision HF-C104 includes an integrated buzzer for audible notification. The manufacturer’s technical documentation specifies an alarm sound pressure level of 75dB at 1 metre for the panel’s alarm function.
In addition to the internal audible indication, the panel provides dedicated fire bell outputs for connecting compatible external notification devices.
Multiple Communication Interfaces
The Hikvision HF-C104 Fire Alarm Control Panel includes several interfaces for system integration and configuration. These include one Ethernet interface, one RS-485 interface and one USB interface.
The panel also provides auxiliary power interfaces and a dedicated 24V output for compatible equipment. These connection options provide flexibility when integrating the control panel into a broader conventional fire alarm installation.
Fire Bell and Relay Outputs
The HF-C104 Fire Alarm Control Panel provides two fire bell outputs for compatible notification equipment. The specifications identify the fire bell outputs as 27.5V/500mA for all outputs.
The panel also provides one fire alarm relay output and one fault relay output. These outputs can be used for suitable external system integration according to the installation design.
Backup Battery Power
The Hikvision 4-Zone Fire Alarm Control Panel supports backup power through two 12V, 2200mAh sealed lead-acid batteries. This backup arrangement is designed to help maintain panel operation when the primary mains supply is unavailable.
The main power supply specification is 110V to 240V AC at 50Hz to 60Hz. The combination of mains and backup power provides an additional layer of operational continuity for the fire alarm control system.
Local Silence, Reset and Self-Test
The HF-C104 Conventional Fire Alarm Panel includes local silence, reset and self-test functions. These features support routine system operation, testing and maintenance.
The self-test functionality can help qualified personnel check the panel’s operating condition, while the silence and reset functions provide local control during appropriate alarm and testing procedures.
Wall or Built-In Installation
The Hikvision HF-C104 features an ultra-slim metal cabinet with hidden hinges. The design supports wall mounting as well as built-in installation, providing flexibility for different building layouts.
The panel measures approximately 300mm wide, 220mm high and 80mm deep. Its metal enclosure is designed for professional fire alarm system installations.
Communication Distance
The Hikvision HF-C104 Fire Alarm Control Panel supports a maximum communication distance of up to 500 metres when using the specified RVS 2 × 1.5mm² flame-retardant cable configuration.
The actual achievable wiring distance depends on the installation, connected devices, cable specification and applicable system requirements. Professional installation is recommended to ensure correct system performance.
Operating Conditions
The HF-C104 Conventional Fire Alarm Panel is specified for an operating temperature range of -10°C to +55°C. Its specified operating humidity range is 5% to 95% relative humidity without condensation.
These specifications allow the panel to be used across a variety of suitable indoor fire alarm environments, provided the installation conditions remain within the manufacturer’s stated operating requirements.
Suitable Applications
The Hikvision 4-Zone Fire Alarm Control Panel can be used as the central control unit for suitable conventional fire alarm installations, including:
- Commercial buildings
- Offices
- Factories
- Warehouses
- Small and medium-sized facilities
- Educational buildings
- Residential and multi-unit properties
- Other suitable conventional fire alarm installations
Professional Conventional Fire Detection
The Hikvision HF-C104 Fire Alarm Control Panel provides centralized control and monitoring for a conventional fire detection system. Its four-zone architecture allows different areas of a building to be separately monitored while supporting a substantial number of conventional devices.
With dedicated alarm and fault outputs, multiple communication interfaces, backup power and built-in testing functions, the panel provides the core control functions required for an appropriately designed conventional fire alarm system.
Technical Specifications
- Model: HF-C104
- System type: Conventional fire alarm control panel
- Zones: 4
- Devices per zone: Up to 32 conventional devices
- Total rated capacity: Up to 128 conventional devices
- Main power: 110V–240V AC, 50Hz–60Hz
- Backup power: 2 × 12V, 2200mAh sealed lead-acid batteries
- Communication distance: Up to 500m with specified cable
- Alarm sound pressure: 75dB @ 1m
- Ethernet: 1 interface
- RS-485: 1 interface
- USB: 1 interface
- Fire bell output: 2
- Fire alarm relay: 1
- Fault relay: 1
- 24V output: 1, 500mA
- Dimensions: 300 × 220 × 80mm
- Operating temperature: -10°C to +55°C
- Operating humidity: 5%–95% RH, non-condensing
- Enclosure: Metal
- Weight: Approximately 4.9kg with batteries and packaging
Why Choose Hikvision HF-C104?
The Hikvision HF-C104 Fire Alarm Control Panel combines four-zone conventional fire detection with support for up to 128 conventional devices. Its multiple interfaces, backup battery system, alarm and fault outputs, self-test capability and flexible installation options make it suitable for appropriately designed conventional fire alarm systems.
The panel should be installed, configured, tested and maintained by appropriately qualified personnel in accordance with the manufacturer’s instructions and applicable local fire safety regulations.
FAQs
What is the Hikvision HF-C104 Fire Alarm Control Panel?
The Hikvision HF-C104 is a 4-zone conventional fire alarm control panel designed to monitor and control compatible conventional fire detection and alarm devices.
How many zones does the HF-C104 have?
The HF-C104 has four conventional fire alarm zones.
How many devices can the HF-C104 support?
The panel supports up to 32 conventional devices per zone, providing a rated total capacity of up to 128 devices.
What devices can be connected to the HF-C104?
Compatible devices can include conventional smoke detectors, heat detectors, manual call points and suitable notification devices such as sounders and fire bells.
Does the Hikvision HF-C104 have battery backup?
Yes. The panel supports two 12V, 2200mAh sealed lead-acid backup batteries.
Does the HF-C104 support Ethernet?
Yes. The HF-C104 includes one Ethernet interface along with RS-485 and USB interfaces.
Does the HF-C104 have a self-test function?
Yes. The panel includes a self-test function along with local silence and reset functions.
What is the communication distance of the HF-C104?
The specified maximum communication distance is up to 500 metres using the recommended RVS 2 × 1.5mm² flame-retardant cable configuration.
What is the power supply of the Hikvision HF-C104?
The main power supply is 110V–240V AC at 50Hz–60Hz, with two 12V, 2200mAh backup batteries.
What are the dimensions of the HF-C104?
The panel measures approximately 300mm wide × 220mm high × 80mm deep.
What is the operating temperature of the HF-C104?
The specified operating temperature range is -10°C to +55°C.
Related products
₨30,000.00
₨4,500.00
₨99,000.00
₨36,000.00

Hikvision 4-Zone Conventional Fire Alarm Control Panel – HF-C104

Hikvision HF-C104 Fire Alarm Control Panel is a 4-zone conventional fire alarm panel supporting up to 32 conventional devices per zone, with Ethernet, RS-485 and battery backup.
In Stock
Shop With Confidence

Product Description:
Hikvision HF-C104 Fire Alarm Control Panel is a 4-zone conventional fire alarm control panel designed to manage and monitor conventional fire detection devices across multiple protected areas. The HF-C104 supports up to 32 conventional devices per zone, providing a total capacity of up to 128 devices for suitable fire alarm installations.
The Hikvision 4-Zone Fire Alarm Control Panel can work with compatible conventional smoke detectors, heat detectors, manual call points and notification devices to create a complete fire detection and alarm system. Its combination of zone monitoring, alarm outputs, fault monitoring and multiple communication interfaces makes it suitable for a range of commercial and industrial installations.
Key Features
- 4 conventional fire alarm zones
- Up to 32 conventional devices per zone
- Up to 128 conventional devices in total
- Supports smoke detectors, heat detectors and manual call points
- Fire bell outputs
- Fire alarm relay output
- Fault relay output
- Ethernet interface
- RS-485 interface
- USB interface
- 4 auxiliary power interfaces
- 24V auxiliary output
- Local silence function
- Reset function
- Self-test function
- Metal cabinet construction
- 110V–240V AC main power supply
- Two 12V, 2200mAh backup batteries
4-Zone Conventional Fire Alarm Panel
The HF-C104 Conventional Fire Alarm Panel provides four independent detection zones for organizing and monitoring different areas of a building. Each zone can support up to 32 compatible conventional devices, giving the panel a maximum rated capacity of 128 conventional devices.
Zone-based monitoring makes it easier for users to identify the affected area when a fire alarm or fault condition occurs. The system can monitor connected devices and wiring conditions, helping provide clear information about the status of the fire detection installation.
Wide Device Compatibility
The Hikvision HF-C104 Fire Alarm Control Panel is designed to work with compatible conventional fire detection and alarm devices. These can include smoke detectors, heat detectors, manual call points, sounders, bells and other compatible notification equipment.
This allows installers to configure an appropriate conventional fire alarm system according to the requirements of the protected building. Device selection and system configuration should always be based on the specific fire risks, building layout and applicable fire safety requirements.
Up to 128 Conventional Devices
The Hikvision 4-Zone Fire Alarm Control Panel supports up to 32 conventional devices on each zone. With four zones available, the HF-C104 provides a rated capacity of up to 128 conventional devices.
This capacity makes the panel suitable for small and medium-sized fire protection installations where multiple areas need to be monitored from a central control point.
Fire Alarm and Fault Monitoring
The HF-C104 Conventional Fire Alarm Panel provides dedicated indicators and monitoring functions for fire alarm and fault conditions. The panel can identify alarm conditions and provide corresponding visual and audible indications.
The system also includes fire alarm and fault relay outputs, allowing compatible external equipment or monitoring systems to receive the relevant status signals. Correct installation and configuration should be performed by qualified personnel.
Integrated Audible Alarm
The Hikvision HF-C104 includes an integrated buzzer for audible notification. The manufacturer’s technical documentation specifies an alarm sound pressure level of 75dB at 1 metre for the panel’s alarm function.
In addition to the internal audible indication, the panel provides dedicated fire bell outputs for connecting compatible external notification devices.
Multiple Communication Interfaces
The Hikvision HF-C104 Fire Alarm Control Panel includes several interfaces for system integration and configuration. These include one Ethernet interface, one RS-485 interface and one USB interface.
The panel also provides auxiliary power interfaces and a dedicated 24V output for compatible equipment. These connection options provide flexibility when integrating the control panel into a broader conventional fire alarm installation.
Fire Bell and Relay Outputs
The HF-C104 Fire Alarm Control Panel provides two fire bell outputs for compatible notification equipment. The specifications identify the fire bell outputs as 27.5V/500mA for all outputs.
The panel also provides one fire alarm relay output and one fault relay output. These outputs can be used for suitable external system integration according to the installation design.
Backup Battery Power
The Hikvision 4-Zone Fire Alarm Control Panel supports backup power through two 12V, 2200mAh sealed lead-acid batteries. This backup arrangement is designed to help maintain panel operation when the primary mains supply is unavailable.
The main power supply specification is 110V to 240V AC at 50Hz to 60Hz. The combination of mains and backup power provides an additional layer of operational continuity for the fire alarm control system.
Local Silence, Reset and Self-Test
The HF-C104 Conventional Fire Alarm Panel includes local silence, reset and self-test functions. These features support routine system operation, testing and maintenance.
The self-test functionality can help qualified personnel check the panel’s operating condition, while the silence and reset functions provide local control during appropriate alarm and testing procedures.
Wall or Built-In Installation
The Hikvision HF-C104 features an ultra-slim metal cabinet with hidden hinges. The design supports wall mounting as well as built-in installation, providing flexibility for different building layouts.
The panel measures approximately 300mm wide, 220mm high and 80mm deep. Its metal enclosure is designed for professional fire alarm system installations.
Communication Distance
The Hikvision HF-C104 Fire Alarm Control Panel supports a maximum communication distance of up to 500 metres when using the specified RVS 2 × 1.5mm² flame-retardant cable configuration.
The actual achievable wiring distance depends on the installation, connected devices, cable specification and applicable system requirements. Professional installation is recommended to ensure correct system performance.
Operating Conditions
The HF-C104 Conventional Fire Alarm Panel is specified for an operating temperature range of -10°C to +55°C. Its specified operating humidity range is 5% to 95% relative humidity without condensation.
These specifications allow the panel to be used across a variety of suitable indoor fire alarm environments, provided the installation conditions remain within the manufacturer’s stated operating requirements.
Suitable Applications
The Hikvision 4-Zone Fire Alarm Control Panel can be used as the central control unit for suitable conventional fire alarm installations, including:
- Commercial buildings
- Offices
- Factories
- Warehouses
- Small and medium-sized facilities
- Educational buildings
- Residential and multi-unit properties
- Other suitable conventional fire alarm installations
Professional Conventional Fire Detection
The Hikvision HF-C104 Fire Alarm Control Panel provides centralized control and monitoring for a conventional fire detection system. Its four-zone architecture allows different areas of a building to be separately monitored while supporting a substantial number of conventional devices.
With dedicated alarm and fault outputs, multiple communication interfaces, backup power and built-in testing functions, the panel provides the core control functions required for an appropriately designed conventional fire alarm system.
Technical Specifications
- Model: HF-C104
- System type: Conventional fire alarm control panel
- Zones: 4
- Devices per zone: Up to 32 conventional devices
- Total rated capacity: Up to 128 conventional devices
- Main power: 110V–240V AC, 50Hz–60Hz
- Backup power: 2 × 12V, 2200mAh sealed lead-acid batteries
- Communication distance: Up to 500m with specified cable
- Alarm sound pressure: 75dB @ 1m
- Ethernet: 1 interface
- RS-485: 1 interface
- USB: 1 interface
- Fire bell output: 2
- Fire alarm relay: 1
- Fault relay: 1
- 24V output: 1, 500mA
- Dimensions: 300 × 220 × 80mm
- Operating temperature: -10°C to +55°C
- Operating humidity: 5%–95% RH, non-condensing
- Enclosure: Metal
- Weight: Approximately 4.9kg with batteries and packaging
Why Choose Hikvision HF-C104?
The Hikvision HF-C104 Fire Alarm Control Panel combines four-zone conventional fire detection with support for up to 128 conventional devices. Its multiple interfaces, backup battery system, alarm and fault outputs, self-test capability and flexible installation options make it suitable for appropriately designed conventional fire alarm systems.
The panel should be installed, configured, tested and maintained by appropriately qualified personnel in accordance with the manufacturer’s instructions and applicable local fire safety regulations.
FAQs
What is the Hikvision HF-C104 Fire Alarm Control Panel?
The Hikvision HF-C104 is a 4-zone conventional fire alarm control panel designed to monitor and control compatible conventional fire detection and alarm devices.
How many zones does the HF-C104 have?
The HF-C104 has four conventional fire alarm zones.
How many devices can the HF-C104 support?
The panel supports up to 32 conventional devices per zone, providing a rated total capacity of up to 128 devices.
What devices can be connected to the HF-C104?
Compatible devices can include conventional smoke detectors, heat detectors, manual call points and suitable notification devices such as sounders and fire bells.
Does the Hikvision HF-C104 have battery backup?
Yes. The panel supports two 12V, 2200mAh sealed lead-acid backup batteries.
Does the HF-C104 support Ethernet?
Yes. The HF-C104 includes one Ethernet interface along with RS-485 and USB interfaces.
Does the HF-C104 have a self-test function?
Yes. The panel includes a self-test function along with local silence and reset functions.
What is the communication distance of the HF-C104?
The specified maximum communication distance is up to 500 metres using the recommended RVS 2 × 1.5mm² flame-retardant cable configuration.
What is the power supply of the Hikvision HF-C104?
The main power supply is 110V–240V AC at 50Hz–60Hz, with two 12V, 2200mAh backup batteries.
What are the dimensions of the HF-C104?
The panel measures approximately 300mm wide × 220mm high × 80mm deep.
What is the operating temperature of the HF-C104?
The specified operating temperature range is -10°C to +55°C.